Pulsafeeder J61088 Injection Check/Back Pressure Valve Assembly – Precision Chemical Injection & Flow Control
$120.70 Original price was: $120.70.$115.80Current price is: $115.80.4% OFF
The Pulsafeeder J61088 Injection Check / Back Pressure Valve Assembly is a genuine OEM replacement component designed to provide accurate and reliable chemical injection in Pulsafeeder metering pump systems. By combining an injection check valve and back pressure valve into a single assembly, it helps prevent backflow while maintaining consistent discharge pressure for precise chemical dosing.
Built with durable, chemical-resistant materials, the J61088 is compatible with Pulsatron® and other Pulsafeeder pumps equipped with KVC1 wet end codes. It features a 3/8-inch OD tubing connection with a coupling nut and a 1/2-inch NPT male injection connection, allowing for fast, secure installation in a variety of chemical feed systems.
The Pulsafeeder J61088 Injection Check / Back Pressure Valve is an excellent choice for maintaining reliable chemical metering in water treatment, cooling towers, boilers, wastewater treatment, agricultural chemical injection, and industrial process applications. Its compact OEM design helps improve dosing accuracy, protects the metering pump from reverse flow, and supports long-term system performance.
Technical Specifications
| Specification | Details |
|---|---|
| Model | Pulsafeeder J61088 |
| Manufacturer Part Number | J61088 |
| Brand | Pulsafeeder |
| Product Type | Injection Check / Back Pressure Valve Assembly |
| Valve Type | Combination Injection Check Valve and Back Pressure Valve |
| Function | Prevents Backflow and Maintains Constant Discharge Pressure for Accurate Chemical Metering |
| Compatible Pumps | Pulsatron® and Other Pulsafeeder Metering Pumps with KVC1 Wet End Codes |
| Tubing Connection | 3/8 in. OD Tubing with Coupling Nut |
| Injection Connection | 1/2 in. NPT Male |
| Flow Direction | One-Way Chemical Injection |
| Construction | Chemical-Resistant Materials |
| OEM Quality | Genuine Pulsafeeder Replacement Part |
| Installation | Direct Replacement for Compatible Pulsafeeder Metering Pumps |
| Applications | Water Treatment Systems, Chemical Feed Systems, Cooling Towers, Boiler Systems, Wastewater Treatment, Municipal Water Systems, Agricultural Chemical Injection, Industrial Process Systems |
| Features | Dual-Function Valve Design, Reverse Flow Prevention, Stable Back Pressure, Compact Construction, Easy Installation |
Precision Chemical Dosing with the Pulsafeeder J61088 Injection Check Back Pressure Valve
The Pulsafeeder J61088 Injection Check Back Pressure Valve improves the performance of chemical feed systems by combining two important functions into one compact assembly. It works as both an injection check valve and a back pressure valve. As a result, it helps deliver accurate chemical dosing while preventing reverse flow.
The J61088 valve assembly allows chemicals to flow in one direction only. Therefore, it protects the metering pump and helps maintain reliable system performance. It also creates steady discharge pressure, which allows diaphragm metering pumps to deliver accurate and repeatable chemical dosing.
The valve fits Pulsatron® metering pumps and other compatible Pulsafeeder pumps with KVC1 wet end codes. In addition, it features a 3/8-inch OD tubing connection with a coupling nut and a 1/2-inch NPT male injection connection. This design makes installation fast and secure.
Pulsafeeder manufactures the valve from durable, chemical-resistant materials. Consequently, it performs well with chlorine and many other common water treatment chemicals. It also supports reliable operation in water treatment systems, cooling towers, boiler systems, wastewater treatment, municipal water systems, and industrial process applications.
Whether you replace a worn valve or upgrade an existing chemical feed system, the Pulsafeeder J61088 Injection Check Back Pressure Valve delivers dependable OEM performance. Furthermore, it helps improve dosing accuracy, protects the metering pump, and extends system service life.
Available from Water Treatment Supply, the Pulsafeeder J61088 Injection Check Back Pressure Valve provides reliable flow control and consistent chemical injection. As a result, it helps keep water treatment systems operating safely and efficiently.
Specifications and Applications of the Pulsafeeder J61088 Injection Check Back Pressure Valve Assembly
The Pulsafeeder J61088 injection check back pressure valve is engineered to improve dosing accuracy by maintaining consistent discharge pressure while preventing reverse chemical flow. Its dual-function design reduces the number of system components while improving operational reliability and simplifying installation.
Use Cases & Industry Applications:
- Water Treatment Systems
Ensures accurate chemical injection for potable water and industrial water treatment applications. - Cooling Tower Chemical Feed
Maintains proper dosing of scale inhibitors, corrosion inhibitors, and biocides for efficient cooling tower operation. - Boiler Water Treatment
Provides stable chemical injection for corrosion protection and scale prevention in boiler systems. - Wastewater Treatment
Supports precise dosing of treatment chemicals for effective wastewater processing and contaminant control. - Agricultural Chemical Injection
Delivers reliable chemical injection for irrigation, fertigation, and agricultural treatment systems. - Industrial Chemical Feed Systems
Maintains one-way flow and consistent back pressure for dependable operation of diaphragm metering pumps in manufacturing and process industries.
No replacement parts listed for this item yet.
FAQs
1. What is the Pulsafeeder J61088 injection check back pressure valve used for?
The J61088 combines a check valve and back pressure valve into one assembly, preventing reverse flow while maintaining stable discharge pressure for accurate chemical dosing.
2. Which pumps are compatible with the J61088 valve assembly?
The valve is designed for Pulsatron® and other Pulsafeeder metering pumps equipped with KVC1 wet end codes.
3. What connection sizes does the valve use?
The assembly features a 3/8-inch OD tubing connection with coupling nut and a 1/2-inch NPT male injection connection.
4. Why is back pressure important in a chemical metering system?
Maintaining constant back pressure helps diaphragm metering pumps deliver accurate, repeatable chemical dosing while minimizing fluctuations in system performance.
5. Is the Pulsafeeder J61088 a genuine OEM replacement part?
Yes. The Pulsafeeder J61088 injection check back pressure valve is a genuine OEM replacement engineered for compatibility, durability, and long-term performance.